Hardware Configuration

 

 

You can configure the operation mode of serial ports, enable/disable the Tx ,Rx termination resistors, enable/disable Tx, Rx BIASing resistors either via serial console port or by the provided GUI (Graphic User Interface) configuration utility program (UsbComCfg).

 

 

Configure Hardware via GUI Utility Program

 

 

You must finish the driver and hardware installation first, before proceeding to hardware configuration. The GUI hardware configuration utility program needs to work with the first serial port of the VSCOM USB PRO series Industrial I/O Adapters.

 

Please proceed with the following steps to run the GUI hardware configuration program:

 

1.     Press the CONFIG button for two seconds until the blue LED will light.

 

2.     Insert the ��USB COM Series Driver and Utility�� CD into your CD-ROM.

 

3.     The ��USB COM Series Driver and Utility CD�� dialog box appears.

 

4.     Under ��USB PRO Series Hardward Configuration Utility��, double click ��UsbComCfg�� to run the GUI hardware configuration utility program.

 

5.     When following message appears, select the product model detected under ��Devices:��, and then choose the port number under ��Ports�� to start the serial port hardware configuration.

 

 

              

 

6.     Under ��Mode��, you can select operation mode of serial port.

 

7.     Under ��Control Bits��, you can enable or disable BIASing and termination resistors. This option is only available when the serial port is set to RS-422 and RS-485 mode.

 

 

7.1 Click ��BIAS�� to enable Tx ,Rx BIASing resistors.

If the BIASing resistors are already enabled, click ��BIAS�� again the BIASing resistors will be disabled.

 

When Tx ,Rx BIASing resistors are enabled, the TxD+ (data+) and RxD+ will pull-up with 750 Ohm resistors, and the TxD-(data-) and RxD- will also pull-down with 750 Ohm resistors.

 

7.2 Click ��TxTerm�� to enable the Tx termination resistor.

If the termination resistor is already enabled, click ��TxTerm�� again the Tx termination resistor will be disabled.

 

When Tx termination resistors are enabled, a 120 Ohm termination resistor will be added between the TxD+ (data+) and TxD- (data-).

 

7.3 Click ��RxTerm�� to enable the Rx Termination resistor.

If the termination resistor already enabled, click ��RxTerm�� again the Rx termination resistor will be disabled.

 

When Rx termination resistors are enabled, a 120 Ohm Termination resistor will be added between the RxD+ and RxD-.

 

8.     Wen you finish the hardware configuration setting, double click ��Commit Change�� to save all configuration data into EEPROM. Press the CONFIG button to exit the hardware configuration setting. The blue LED will change to dark. You are in normal operation mode now.

 

9.     When a new VSCOM USB PRO Series Industrial I/O Adapter is attach to system, please double click the ��Search Devices�� to re-start hardware configuration setting for this device.

 

 

Configure Hardware via Serial Console port

 

 

You must finish the driver and hardware installation first, before proceeding to hardware configuration. The serial console port and hardware configuration utility program need to work with the first serial port of the VSCOM USB PRO series Industrial I/O Adapters.

 

You must find from the ��Device Manager�� of Windows the first serial port number of your VSCOM USB PRO Industrial I/O Adapter. Open this serial port with any terminal program (Hyperterminal, or other terminal emulator program), select 38400 bps, 8 Bit, No Parity, 1 stop bit, flow control : none for serial console port. (Note: the default flow control setting of Hyperterminal is ��hardware��, you need to change to ��none�� for proper operation).

 

After opening terminal program for serial console port, you must press the CONFIG button and hold for two seconds until the blue LED will light. Following is an example of the message that will appear, if the product is an USB2-4COM PRO.

 

[4#1] USB2-4COM PRO v1: please press <ENTER> to activate the menu     

 

Hardware Configuration Main Menu.                                                         

 

Press <Enter> to activate the hardware configuration main menu.

The hardware configuration main menu messages are:

 

 0 - Exit        

----------------------------------------------                                 

 1 - Show all port configurations                                

 2 - Change port configurations                              

 3 - Default port configurations                               

 4 - Save port configurations                            

----------------------------------------------                                 

 5 - Show configuration file                           

 6 - Upload configuration file                             

 

 

Press <0> to exit the hardware configuration main menu and the blue LED will change to dark.

 

 

Press <5> to show the hardware configuration file (decimal values)

 

Press <6> to upload the hardware configuration file (decimal values)      

 

Press <1> to show all port hardware configurations, the message are following:

 

Port 1: RS232

Port 2: RS422 (BIAS, TxTerm, RxTerm)

Port 3: RS485 auto, 2-wire with Echo (none)

Port 4: RS485 by RTS, 2-wire no Echo (BIAS, TxTerm)

 

Port 1: RS232

Port 1 is working in RS-232 mode.

 

Port 2: RS422 (BIAS, TxTerm, RxTerm)

Port 2 is working in RS-422 mode. BIASing resistor and Tx , Rx termination resistors are enabled.

 

Port 3: RS485 auto, 2-wire with Echo (none)

Port 3 is working in RS-485 half duplex mode with automatic data receive and transmit control. BIASing resistors and termination resistors are disabled.

 

Port 4: RS485 by RTS, 2-wire no Echo (BIAS, TxTerm)

Port 4 is working in RS-485 half duplex mode. BIASing resistors and Tx termination resistors are enabled. The data receive and transmit control is by RTS signal.

 

 

Press <3> to set all ports in default configurations to RS-232 mode.

After press <3> to set all ports to default configurations, you must press <4> to save default port configurations data into EEPROM.

 

Press <4> to save all configurations data into EEPROM. When the save operation is finished, the screen will show:

 

OK - values were written to the eeprom 

 

Change Port Configuration Menu

 

Press <2> to change port configurations menu, the message are:

 

0 - Back          

---------------              

 1 - Port 1        

 2 - Port 2        

        .                                                         

        .                                                   

---------------              

 x - All Ports    

 

If the adapter is single-port version (USB-COM PRO), ��x�� is 2; dual-port version (USB-2COM PRO), ��x�� is 3; quad-port version (USB2-4COM PRO), ��x�� is 5 and 8-port version (USB2-8COM PRO), ��x�� is 9. For 16-port version (USB2-16COM PRO), x is 17.

 

Press <0> to return to hardware configuration main menu.

 

Press <x> to set all the ports with same hardware configuration.

 

Port Setting Menu.

 

Press <1/2/3�K> to set the port-1, port-2, port-3, etc.

Hardware configuration and port setting menu options include the following:

 

---------------------------------------------------                                   

 0 - Back                             

---------------------------------------------------                                   

 1 - RS485 by RTS, 4-wire                         

 2 - RS485 by RTS, 2-wire no Echo                                

 3 - RS485 by RTS, 2-wire with Echo                                  

 4 - RS485 auto, 4-wire                      

 5 - RS485 auto, 2-wire no Echo                               

 6 - RS485 auto, 2-wire with Echo                                

 7 - RS422         

 8 - RS232         

----------------------------------------------------                                   

 9 - BIAS        

10 - TxTerm          

11 - RxTerm          

 

Press <0> back to change port configurations menu.

Press <1> ~ <8> to select operation mode of serial port. the operation modes are :

 

Operation Mode of Serial Port.

 

 1 - RS485 by RTS, 4-wire--- RS-485 full duplex mode, data receive and transmit control by RTS signal.               

 2 - RS485 by RTS, 2-wire no Echo --- RS-485 half duplex mode, data receive and transmit control by RTS, no transmit data echo.                                  

 3 - RS485 by RTS, 2-wire with Echo--- RS-485 half duplex mode, data receive and transmit control by RTS signal with transmit

data echo.                                  

 4 - RS485 auto, 4-wire--- RS-485 full duplex mode with automatic data receive and transmit control.                     

 5 - RS485 auto, 2-wire no Echo--- RS-485 half duplex mode with automatic data receive and transmit control, no transmit data echo.                          

 6 - RS485 auto, 2-wire with Echo--- RS-485 half duplex mode with automatic data

receive and transmit control, transmit data echo.                                

 7 - RS422   --- RS-422 mode   

 8 - RS232   --- RS-232 mode  

    

 

 

 

BIASing and Termination Resistor.

 

        

Press <9> to enable Tx, Rx BIASing resistors. If the BIASing resistors are already enabled, you can press <9> to disable it.

When Tx ,Rx BIASing resistors are enabled, the TxD+(data+) and RxD+ will pull-up with 750 Ohm resistors. The TxD-(data-) and RxD- will also pull-down with 750 Ohm resistors.

 

Press <10> to enable the Tx termination resistor. If the termination resistor is already enabled, you can press <10> to disable it.

When Tx Termination resistor is enabled, a 120 Ohm termination resistor will be added between the TxD+ (data+) and TxD- (data-).

 

 

Press <11> to enable the Rx termination resistor. If the termination resistor is already enabled, you can press <11> to disable it.

When Tx termination resistors is enabled, a 120 Ohm termination resistor will be added between the RxD+ and RxD-.

 

 

 

 

 

Completion of Serial Port Configuration Setting

 

After finishing the hardware configuration setting of serial port, press <0> twice to return to the hardware configuration main menu.

 

0 - Exit        

----------------------------------------------                                 

 1 - Show all port configurations

 2 - Change port configurations

 3 - Default port configurations

 4 - Save port configurations

----------------------------------------------

 5 - Show configuration file

 6 - Upload configuration file

 

Press <4> to save all configurations data into EEPROM. When save operation is finished, press <0> to exit the hardware configuration main menu. Now, the blue LED changes to dark again. You exit the configuration mode and in the normal operation mode now.

 

 


 

 

LED Indicators

 

The VSCOM USB PRO Series Industrial I/O Adapters are designed with monitor LEDs of TxD & RxD indicating serial port data transmit and receive status, and with Operation Mode LEDs indicating serial port operation mode of RS-232/422/485.

 

Operation Mode and Mode LED Color

 

Operation Mode

Mode LED Color

RS-232

Red

RS-422

Green

RS-485 auto,2-Wire with echo

Orange

RS-485 auto,2-Wire no echo

Orange

RS-485  auto ,4-Wire

Orange

RS-485 by RTS,2-Wire with echo

Orange

RS-485 by RTS,2-Wire no echo

Orange

RS-485 by RTS,4-Wire

Orange