Hardware Setting & Mode Configuration

 

Outside the unit, there are four 4-pin DIP switches which are set to select the mode of operation. You will need to set the switch settings to RS-422 mode, or RS-485 mode, as per the requirements of your application.After setting of switches and connecting power supply to the adapter, you then plug the adapter to USB port to start driver installation. The RS-422 & RS-485 Mode Block Configuration Settings are listed as follows.

 

 

RS-422 & RS-485 Mode Block Configuration

 

 

SW1 (PORT1), SW2 (PORT2), SW3 (PORT3), SW4 (PORT4)

 

 

  Operation  Mode

 S1

 S2

 S3

  S4

RS-422
4 wire with handshaking

 ON

 ON

 

OFF

 

OFF

RS-485
Full Duplex (4 wire)

 ON

 

OFF

 

OFF

 

OFF

Half Duplex (2 wire) 

with Echo

 

OFF

 

OFF

 

OFF

 ON Note

Half Duplex (2 wire )

without Echo

 

OFF

 

OFF

 ON

 ON Note

 

 

Note : In the most common situation , a 120 Ohm termination resistor of TxD (S4 is ON ) is required in a RS485 Half Duplex configuration. Otherwise it is rarely used.

 

 

 

Inside the unit, there are four 6x2 (8pin) header blocks which are jumpered to enable Rx, CTS 120 Ohm termination resistors and Rx, Tx 750 Ohm biasing resistor. You will need to open up the case and set the jumper setting for RS-422 mode or RS-485 mode as per the requirements of your application. Settings are listed as follows.

 

 

 

JP5(PORT1), JP6(PORT2), JP7(PORT3), JP8(PORT4) for Termination and Biasing Option Configuration

 

Jumper

Function

1-2

 

Pull-up  Tx+ to VCC by 750 Ohm Bias resistor.

This jumper should be populated for pull-up Tx+.

3-4

Pull-down Tx- to GND by 750 Ohm Bias resistor.

This jumper should be populated for pull-down Tx-.

5-6

Rx+/- Termination of 120 Ohm.

This jumper should always be populated forRS-422 and RS485 Full-Duplex mode.

7-8

 

Pull-up Rx+ to VCC by 750 Ohm Bias resistor.

This jumper should be populated for pull-up Rx+.

9-10

Pull-down Rx-  to GND by 750 Ohm Bias resistor.

This jumper should be populated for pull-down Rx-.

11-12

CTS Termination of 120 Ohm.

This jumper should always be populated for RS-422 mode.

 

Note : Sometimes, when operating in RS-422 or RS-485, it is necessary to configure

termination and biasing of the data transmission lines. Generally this must be done

in the cabling, since this depends on the installation of connections. Before applying

the option, check your cable specification for proper impedance matching.

 

Biasing of data lines must only occur at a single point anywhere in the cabling. USB‑4COMi-M and USB‑4COMi‑SI-M provide biasing for ease of installation. Please be sure to disable this inside the unit, if your cabling already provides biasing.

 

Termination must not be installed in the middle of the cable. It is only permitted at both ends. Since a computer controlled serial port is almost always at one end of the cable, termination is enabled by default. Rx‑Termination is inside the box, because you hardly ever need to change it. Tx‑Termination is used in Half‑Duplex modes. In this situation data is sent and received via Tx+/- lines. Therefore Tx‑Termination is done via DIP‑Switch (see S4 above).

 

RS-422/485 Pin-outs & Signal Wiring

 

are Setting & Mode Configuration

RS-422 Signal Pin-outs of DB-9 Male

 

Pin 1

TxD- (A)

Pin 2

TxD+(B)

Pin 3

RxD+(B)

Pin 4

RxD-(A)

Pin 5

GND

Pin 6

RTS- (A)

Pin 7

RTS+(B)

Pin 8

CTS+(B)

Pin 9

CTS- (A)

 

 

RS-422 Signal Wiring

 

    l    Point-to-Point 4-Wire Full Duplex

 

    l    RS-422 with Handshaking

 

 

RS-485 4-Wire (Full duplex) Signal Pin-outs of DB-9 Male Connector

 

Pin 1

TxD- (A)

Pin 2

TxD+(B)

Pin 3

RxD+(B)

Pin 4

RxD-(A)

Pin 5

GND

 

RS-485 2-Wire (Half duplex) Signal Pin-outs of DB-9 Male Connector

 

Pin 1

Data- (A)

Pin 2

Data+(B)

Pin 5

GND  

 

RS-485 Signal Wiring

    l       Point-to-Point 4 Wire Full Duplex

 

    l       Multidrop RS-485 2-Wire Half-duplex